This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| computing:nextcloud [2026/09/28 07:05] – oemb1905 | computing:nextcloud [2026/10/14 15:15] (current) – oemb1905 | ||
|---|---|---|---|
| Line 219: | Line 219: | ||
| slow_query_log = ON | slow_query_log = ON | ||
| slow_query_log_file = / | slow_query_log_file = / | ||
| - | long_query_time = 2 | + | long_query_time = 1 |
| - | tmp_table_size | + | log_queries_not_using_indexes |
| - | max_heap_table_size | + | min_examined_row_limit |
| - | innodb_log_file_size | + | log_slow_verbosity |
| - | innodb_flush_log_at_trx_commit | + | |
| - | innodb_buffer_pool_size | + | tmp_table_size |
| - | table_open_cache | + | max_heap_table_size |
| + | sort_buffer_size | ||
| table_definition_cache = 2000 | table_definition_cache = 2000 | ||
| + | table_open_cache = 32586 | ||
| table_open_cache_instances = 8 | table_open_cache_instances = 8 | ||
| open_files_limit = 32768 | open_files_limit = 32768 | ||
| + | |||
| + | innodb_log_file_size = 256M | ||
| + | innodb_buffer_pool_size = 4G | ||
| + | innodb_log_file_size = 256M | ||
| + | innodb_flush_log_at_trx_commit = 1 | ||
| + | innodb_flush_method = O_DIRECT | ||
| </ | </ | ||